Athaip YR-H d11-6161 [#211700926108259]
V0H-58N
[#3700140800]
?
Type:
Fleet Carrier
Distance to arrival:
0 ls
Allegiance:
Independent
Government:
Fleet Carrier
Economy:
Fleet Carrier
Facilities:
Commodities
Shipyard
Outfitting
Contacts, Crew Lounge, Pioneer Supplies, Refuel, Repair, Restock, Universal Cartographics, Vista Genomics
Shipyard
Outfitting
Contacts, Crew Lounge, Pioneer Supplies, Refuel, Repair, Restock, Universal Cartographics, Vista Genomics
Prohibited:
Imperial Slaves, Slaves
Last update: 3/16/24, 10:02 PM
Core Internal |
---|
Reactor Bay | Integrity | Mass | Power | Price | ||
---|---|---|---|---|---|---|
2C | Power Plant | Consumes fuel to power all ship modules. | 51 | 1.3 t | ?? | 17,800 cr |
2B | Power Plant | Consumes fuel to power all ship modules. | 61 | 2 t | ?? | 53,410 cr |
3C | Power Plant | Consumes fuel to power all ship modules. | 64 | 2.5 t | ?? | 56,440 cr |
3B | Power Plant | Consumes fuel to power all ship modules. | 77 | 4 t | ?? | 169,300 cr |
4C | Power Plant | Consumes fuel to power all ship modules. | 80 | 5 t | ?? | 178,900 cr |
4B | Power Plant | Consumes fuel to power all ship modules. | 96 | 8 t | ?? | 536,690 cr |
5C | Power Plant | Consumes fuel to power all ship modules. | 96 | 10 t | ?? | 567,110 cr |
5B | Power Plant | Consumes fuel to power all ship modules. | 115 | 16 t | ?? | 1,701,320 cr |
6C | Power Plant | Consumes fuel to power all ship modules. | 113 | 20 t | ?? | 1,797,730 cr |
6B | Power Plant | Consumes fuel to power all ship modules. | 136 | 32 t | ?? | 5,393,180 cr |
7C | Power Plant | Consumes fuel to power all ship modules. | 131 | 40 t | ?? | 5,698,790 cr |
7B | Power Plant | Consumes fuel to power all ship modules. | 157 | 64 t | ?? | 17,096,370 cr |
8C | Power Plant | Consumes fuel to power all ship modules. | 150 | 80 t | ?? | 18,065,170 cr |
8B | Power Plant | Consumes fuel to power all ship modules. | 180 | 128 t | ?? | 54,195,500 cr |
Thruster Mounting | Integrity | Mass | Power | Price | ||
---|---|---|---|---|---|---|
2C | Thrusters | Normal-space propulsion system. | 51 | 2.5 t | 2.5 MW | 17,800 cr |
2B | Thrusters | Normal-space propulsion system. | 61 | 4 t | 2.75 MW | 53,410 cr |
3C | Thrusters | Normal-space propulsion system. | 64 | 5 t | 3.1 MW | 56,440 cr |
3B | Thrusters | Normal-space propulsion system. | 77 | 8 t | 3.41 MW | 169,300 cr |
4C | Thrusters | Normal-space propulsion system. | 80 | 10 t | 4.1 MW | 178,900 cr |
4B | Thrusters | Normal-space propulsion system. | 96 | 16 t | 4.51 MW | 536,690 cr |
5C | Thrusters | Normal-space propulsion system. | 96 | 20 t | 5.1 MW | 567,110 cr |
5B | Thrusters | Normal-space propulsion system. | 115 | 32 t | 5.61 MW | 1,701,320 cr |
6C | Thrusters | Normal-space propulsion system. | 113 | 40 t | 6.3 MW | 1,797,730 cr |
6B | Thrusters | Normal-space propulsion system. | 136 | 64 t | 6.93 MW | 5,393,180 cr |
7C | Thrusters | Normal-space propulsion system. | 131 | 80 t | 7.6 MW | 5,698,790 cr |
7B | Thrusters | Normal-space propulsion system. | 157 | 128 t | 8.36 MW | 17,096,370 cr |
8C | Thrusters | Normal-space propulsion system. | 150 | 160 t | 9 MW | 18,065,170 cr |
8B | Thrusters | Normal-space propulsion system. | 180 | 256 t | 9.9 MW | 54,195,500 cr |
FSD Housing | Integrity | Mass | Power | Price | ||
---|---|---|---|---|---|---|
2C | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 51 | 2.5 t | 0.2 MW | 17,800 cr |
2B | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 77 | 4 t | 0.25 MW | 53,410 cr |
3C | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 64 | 5 t | 0.3 MW | 56,440 cr |
3B | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 96 | 8 t | 0.38 MW | 169,300 cr |
4C | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 80 | 10 t | 0.3 MW | 178,900 cr |
4B | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 120 | 16 t | 0.38 MW | 536,690 cr |
5C | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 96 | 20 t | 0.4 MW | 567,110 cr |
5B | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 144 | 32 t | 0.5 MW | 1,701,320 cr |
6C | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 113 | 40 t | 0.5 MW | 1,797,730 cr |
6B | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 170 | 64 t | 0.63 MW | 5,393,180 cr |
7C | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 131 | 80 t | 0.6 MW | 5,698,790 cr |
7B | Frame Shift Drive | Device that allows supercruise travel and hyperspace jumps between star systems. | 197 | 128 t | 0.75 MW | 17,096,370 cr |
Power Coupling | Integrity | Mass | Power | Price | ||
---|---|---|---|---|---|---|
1C | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 40 | 1.3 t | 0.4 MW | 3,230 cr |
1B | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 48 | 2 t | 0.44 MW | 8,080 cr |
2C | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 51 | 2.5 t | 0.45 MW | 9,050 cr |
2B | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 61 | 4 t | 0.5 MW | 22,620 cr |
3C | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 64 | 5 t | 0.5 MW | 25,330 cr |
3B | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 77 | 8 t | 0.55 MW | 63,330 cr |
4C | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 80 | 10 t | 0.56 MW | 70,930 cr |
4B | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 96 | 16 t | 0.62 MW | 177,330 cr |
5C | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 96 | 20 t | 0.62 MW | 198,610 cr |
5B | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 115 | 32 t | 0.68 MW | 496,530 cr |
6C | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 113 | 40 t | 0.68 MW | 556,110 cr |
6B | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 136 | 64 t | 0.75 MW | 1,390,280 cr |
7D | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 105 | 32 t | 0.67 MW | 622,840 cr |
7C | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 131 | 80 t | 0.74 MW | 1,557,110 cr |
8D | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 120 | 64 t | 0.72 MW | 1,743,960 cr |
8C | Power Distributor | Distribution system for ENG, SYS and WEP capacitors. | 150 | 160 t | 0.8 MW | 4,359,900 cr |
Sensor Suite | Integrity | Mass | Power | Price | ||
---|---|---|---|---|---|---|
1A | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 44 | 1.3 t | 0.6 MW | 20,200 cr |
2A | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 56 | 2.5 t | 0.69 MW | 56,550 cr |
3A | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 70 | 5 t | 0.84 MW | 158,330 cr |
4A | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 88 | 10 t | 1.02 MW | 443,330 cr |
5B | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 115 | 32 t | 0.68 MW | 496,530 cr |
5A | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 106 | 20 t | 1.23 MW | 1,241,320 cr |
6B | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 136 | 64 t | 0.83 MW | 1,390,280 cr |
6A | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 124 | 40 t | 1.5 MW | 3,475,690 cr |
7B | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 157 | 128 t | 0.97 MW | 3,892,770 cr |
7A | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 144 | 80 t | 1.77 MW | 9,731,930 cr |
8B | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 180 | 256 t | 1.14 MW | 10,899,760 cr |
8A | Sensors | Standard suite providing basic detection, identification and targeting capabilities. | 165 | 160 t | 2.07 MW | 27,249,390 cr |
Optional Internal |
---|
Shield Generators | Integrity | Mass | Power | Price | ||
---|---|---|---|---|---|---|
1C | Bi-Weave Shield Generator | An alternative shield generator that sacrifices overall shield strength for a much faster recharge rate. | 40 | 1.3 t | 1.2 MW | 7,710 cr |
2C | Bi-Weave Shield Generator | An alternative shield generator that sacrifices overall shield strength for a much faster recharge rate. | 51 | 2.5 t | 1.5 MW | 26,710 cr |
2B | Shield Generator | Forms a continually regenerating protective energy shield around the vessel. | 71 | 4 t | 1.8 MW | 53,410 cr |
3C | Bi-Weave Shield Generator | An alternative shield generator that sacrifices overall shield strength for a much faster recharge rate. | 64 | 5 t | 1.8 MW | 84,650 cr |
3B | Shield Generator | Forms a continually regenerating protective energy shield around the vessel. | 90 | 8 t | 2.16 MW | 169,300 cr |
4C | Bi-Weave Shield Generator | An alternative shield generator that sacrifices overall shield strength for a much faster recharge rate. | 80 | 10 t | 2.2 MW | 268,350 cr |
4B | Shield Generator | Forms a continually regenerating protective energy shield around the vessel. | 112 | 16 t | 2.64 MW | 536,690 cr |
5C | Bi-Weave Shield Generator | An alternative shield generator that sacrifices overall shield strength for a much faster recharge rate. | 96 | 20 t | 2.6 MW | 850,660 cr |
5B | Shield Generator | Forms a continually regenerating protective energy shield around the vessel. | 134 | 32 t | 3.12 MW | 1,701,320 cr |
6C | Bi-Weave Shield Generator | An alternative shield generator that sacrifices overall shield strength for a much faster recharge rate. | 113 | 40 t | 3.1 MW | 2,696,600 cr |
6B | Shield Generator | Forms a continually regenerating protective energy shield around the vessel. | 158 | 64 t | 3.72 MW | 5,393,180 cr |
7C | Bi-Weave Shield Generator | An alternative shield generator that sacrifices overall shield strength for a much faster recharge rate. | 131 | 80 t | 3.5 MW | 8,548,200 cr |
7B | Shield Generator | Forms a continually regenerating protective energy shield around the vessel. | 183 | 128 t | 4.2 MW | 17,096,370 cr |
8C | Bi-Weave Shield Generator | An alternative shield generator that sacrifices overall shield strength for a much faster recharge rate. | 150 | 160 t | 4 MW | 27,097,750 cr |
8B | Shield Generator | Forms a continually regenerating protective energy shield around the vessel. | 210 | 256 t | 4.8 MW | 54,195,500 cr |
Surface Scanners | Integrity | Mass | Power | Price | ||
---|---|---|---|---|---|---|
1C | Detailed Surface Scanner | Advanced stellar body scanner used during exploration. | 20 | 0 t | 0 MW | 250,000 cr |
Utility Mount |
---|
Pulse Wave Analyser | Integrity | Mass | Power | Price | ||
---|---|---|---|---|---|---|
0D | Pulse Wave Analyser | Pulse wave analysers are used to detect anomalous readings within solid objects, more specifically within asteroid fields. | ?? | 1.3 t | 0.4 MW | ?? |
0C | Pulse Wave Analyser | Pulse wave analysers are used to detect anomalous readings within solid objects, more specifically within asteroid fields. | ?? | 1.3 t | 0.8 MW | ?? |
0B | Pulse Wave Analyser | Pulse wave analysers are used to detect anomalous readings within solid objects, more specifically within asteroid fields. | ?? | 1.3 t | 1.6 MW | ?? |
0A | Pulse Wave Analyser | Pulse wave analysers are used to detect anomalous readings within solid objects, more specifically within asteroid fields. | ?? | 1.3 t | 3.2 MW | ?? |